NEET PG · Radiology

Radiology Physics and Modalities

22 practice questions with full step-by-step solutions — free, no sign-up.

Reviewed by (19 years teaching)Written with AI helpReport a mistake

This chapter has

7
easy
11
medium
4
hard

Radiology Physics and Modalities — solved practice questions

6 NEET PG Radiology questions with step-by-step solutions. Attempt each, then reveal the answer.

These worked examples are not in the timed test, so you can study them first.

  1. Q1easyReport

    The SI unit of absorbed radiation dose is:

    • AGray
    • BBecquerel
    • CRoentgen
    • DSievert
    Show answer & solution

    Correct answer: (A) Gray

    Absorbed dose is the energy deposited per unit mass of tissue. Its SI unit is the gray (1 Gy = 1 J/kg). The sievert is the unit of equivalent and effective dose, which are weighted for radiation type and tissue. The becquerel measures radioactivity, not dose.
  2. Q2easyReport

    Effective dose, which accounts for both radiation type and tissue sensitivity, is expressed in:

    • ASievert
    • BCoulomb per kg
    • CGray
    • DCurie
    Show answer & solution

    Correct answer: (A) Sievert

    Equivalent dose and effective dose are expressed in sieverts (Sv). They are calculated from the absorbed dose by applying radiation weighting factors and tissue weighting factors. The gray measures absorbed dose without any weighting. The curie is an old unit of radioactivity.
  3. Q3easyReport

    On the Hounsfield scale used in CT, the attenuation value of pure water is defined as:

    • A-1000 HU
    • B+1000 HU
    • C+100 HU
    • D0 HU
    Show answer & solution

    Correct answer: (D) 0 HU

    The Hounsfield scale is set so that water is 0 HU and air is -1000 HU. Dense cortical bone is roughly +1000 HU or higher. Fat has negative values, around -50 to -100 HU.
  4. Q4easyReport

    On CT, air has an attenuation value of approximately:

    • A-1000 HU
    • B0 HU
    • C-100 HU
    • D+40 HU
    Show answer & solution

    Correct answer: (A) -1000 HU

    Air is the reference point at the bottom of the Hounsfield scale, -1000 HU, and water is set at 0 HU. Values around -100 HU are typical of fat. Values around +40 HU are typical of soft tissue or blood.
  5. Q5easyReport

    Computed tomography (CT) was developed by:

    • AWilhelm Roentgen
    • BPaul Lauterbur
    • CGodfrey Hounsfield
    • DHenri Becquerel
    Show answer & solution

    Correct answer: (C) Godfrey Hounsfield

    Godfrey Hounsfield built the first clinical CT scanner, and he shared the 1979 Nobel Prize with Allan Cormack. The CT attenuation scale is named after him. Roentgen discovered X-rays, Lauterbur contributed to MRI, and Becquerel discovered radioactivity.
  6. Q6mediumReport

    Ultrasound waves in a diagnostic transducer are generated by which principle?

    • AFaraday's electromagnetic induction
    • BPiezoelectric effect
    • CThermionic emission
    • DPhotoelectric effect
    Show answer & solution

    Correct answer: (B) Piezoelectric effect

    Ultrasound transducers contain piezoelectric crystals, such as lead zirconate titanate. These crystals vibrate when a voltage is applied, and they produce a voltage when returning echoes strike them. Thermionic emission is how an X-ray tube cathode releases electrons, and the photoelectric effect is an X-ray interaction with matter.

Ready to test yourself? Take the 16-question Radiology Physics and Modalities test →